Save America Water WELCOME Ei Cooling Tower Blowdown Initiative
23 Slides6.88 MB
Save America Water WELCOME Ei Cooling Tower Blowdown Initiative
Ei Cooling Tower Blowdown Initiative AGENDA Benefits WCTI Technology Equipment The World’s Busiest Airport Q&A
Ei Cooling Tower Blowdown Initiative WCTI technology it’s Nature’s Way. WCTI technology saves more water and more money than any other method. It Is Double Green .
Ei Cooling Tower Blowdown Initiative Eliminates blowdown and the constant chemical discharge too! Clients include Apple, Boeing, Microsoft , Universal Studios and Verizon.
Ei Cooling Tower Blowdown Initiative Additional Benefits Fast ROI Retrofits are easy. LEED points are available. Works with well water. Works with gray water.
Ei Cooling Tower Blowdown Initiative Evaporative Cooling
Ei Cooling Tower Blowdown Initiative Evaporative Cooling
Ei Cooling Tower Blowdown Initiative Machines Hate Tap Water
Ei Cooling Tower Blowdown Initiative Water Must Be Treated to Prevent Scale, Corrosion & Bio-fouling
Ei Cooling Tower Blowdown Initiative Traditional Chemical Treatment
Ei Cooling Tower Blowdown Initiative Typical Chemicals Used
Ei Cooling Tower Blowdown Initiative Traditional Chemical Treatment Wastes Water As the water evaporates, the chemicals are left behind. To keep the chemicals in effective balance, water must be drained and more water brought in. This “blowdown” can be 10 to 35 percent of water consumed. Water and sewer costs for this “blowdown” can be significant!
Ei Cooling Tower Blowdown Initiative Dan Duke, founder of WCTI, discovered in 2000 if you use a super softener to remove the hardness(calcium and magnesium) down to a gnat’s hair, Mother Nature will give you corrosion and bio-fouling protection, for free!
Ei Cooling Tower Blowdown Initiative WCTI Methodology 1. High Efficiency Softener (HES) uses sodium (Na) zeolite resin to eliminate the hardness(Ca and Mg) in the tower supply water. 2. Resin absorbs Ca and Mg and exchanges with Na for a one-to-one exchange. Naturally occurring pH climbs to 9.3 10.0 and along with the high TDS(total dissolved solids) prevents biological growth. 3. Silica is naturally polymerized with the increased pH and high TDS in the absence of hardness. 4. The resulting NaSiO2, sodium silicate, is considered an excellent corrosion inhibitor and is naturally formed under WCTI conditions. RESULTS: NO scale and effective control of corrosion and biological growth – eliminates the need for chemical additives and blowdown
Ei Cooling Tower Blowdown Initiative SILICA BASED TECHNOLOGY
Ei Cooling Tower Blowdown Initiative SIMPLE EQUIPMENT SET-UPS
Ei Cooling Tower Blowdown Initiative RPA
RPA Supports Your Water & Asset Management Dai ly E ma ile d S tat u s Re p ort s on Criti cal p l a n t c o n t ro l re q u i r e m e n t s such as: Wate r use P re s s u re Re g e n erati on Powe r fa i l u re a l a r m 18
Ei Cooling Tower Blowdown Initiative Ei Water Use & Toxicity Platform Ei Cooling Tower Blowdown Initiative The Ei team visited the WCTI installation at the Verizon data center in Tampa, Florida on May 22, 2013 As a strategic partner, Ei introduced WCTI to prospects including: Georgia World Congress Center Hartsfield-Jackson Atlanta International Airport.
Ei Cooling Tower Blowdown Initiative World’s Busiest Airport Preliminary Numbers & Assumptions Two Chiller Plants: 10,000 tons & 16,500 tons Average Annual Load Factor: 20% Water & Sewer Source: City of Atlanta Water/Sewer Cost is 28 per 1000 gallons Cooling Water Treatment: Chemical
Ei Cooling Tower Blowdown Initiative World’s Busiest Airport Preliminary Analysis Save 7 to 10 million gallons of water each year Save 185,000 to 250,000 per year in water/sewer cost
Ei Cooling Tower Blowdown Initiative No Other Method Saves As Much Water
Ei Cooling Tower Blowdown Initiative Return On Investment is Fast 6 – 24 Months